翻訳と辞書
Words near each other
・ Frequency following response
・ Frequency format hypothesis
・ Frequency frogging
・ Frequency grid
・ Frequency Level Expander
・ Frequency meter
・ Frequency mixer
・ Frequency modulation
・ Frequency modulation synthesis
・ Frequency multiplier
・ Frequency of optimum transmission
・ Frequency offset
・ Frequency partition of a graph
・ Frequency response
・ Frequency scaling
Frequency scanning interferometry
・ Frequency selective surface
・ Frequency separation
・ Frequency sharing
・ Frequency shift
・ Frequency specific microcurrent
・ Frequency standard
・ Frequency synthesizer
・ Frequency Unknown
・ Frequency-Agile Solar Radiotelescope
・ Frequency-change signaling
・ Frequency-dependent foraging by pollinators
・ Frequency-dependent selection
・ Frequency-division multiple access
・ Frequency-division multiplexing


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Frequency scanning interferometry : ウィキペディア英語版
Frequency scanning interferometry
Frequency scanning interferometry (FSI) is an absolute distance measurement technique, for measuring the distance between a pair of points, along a line-of-sight.
The power of the FSI technique lies in its ability to make many such distance measurements, simultaneously.

For each distance to be measured, a measurement interferometer is built using optical components placed at each end of a line-of-sight.
The optical path of each measurement interferometer is compared to the optical path in a reference interferometer, by scanning the frequency of a laser (connected to all interferometers in the system) and counting fringe cycles produced in the return signals from each interferometer.
The length of each measurement interferometer is given in units of reference length by the ratio of measurement interferometer to reference interferometer fringes.
To give an example: A frequency scan might produce 100 fringe cycles in the measurement interferometer and 50 in the reference interferometer. The measured interferometer is therefore twice the length of reference interferometer, to first order (ignoring systematic errors - see below).
==Reference interferometer precautions==
A typical reference interferometer is held at a stable length in a controlled environment, to reduce the dominant systematic errors which arise from changes in optical path which occur during the laser frequency scan.